This is Paper A of the C08 note on dismounted and man-worn soldier power, and it settles the first question an OEM battery engineer has to answer before any cell or pack is sized: how does a soldier's worn power system actually work, and what kind of electrical load does it present? A dismounted infantryman carries a radio, a satellite terminal, a situational-awareness device, navigation, night vision and a set of sensors, and for a long time each of these was fed by its own disposable battery, so a seventy-two-hour mission meant carrying a large stack of many different cells. The modern answer is a central rechargeable battery worn against the body, a smart power manager that distributes energy to every device at the voltage it needs, and a scavenging path that recharges the central pack from solar, vehicle or found power. This paper maps the burden problem, the centralized managed architecture and the smart-battery, harness and interface standards that make it work, states the mixed standby-plus-burst load the battery sees, and states honestly where sealed nickel-metal hydride is the correct chemistry and where the worn battery's own lithium chemistry is. The selection and sizing work follows in later papers. Every figure that is not a published specification is labelled illustrative, and the binding values for a real project remain the device manual and the agreed pack drawing.
Key fact 1. The starting point is a burden problem called battery proliferation. Published logistics work records that a typical seventy-two-hour dismounted combat load needs up to twenty-three batteries weighing about ten pounds, roughly ten percent of the whole combat load, and the average soldier already carries at least sixty pounds of gear; each device historically had its own disposable cell.
Key fact 2. The modern architecture is centralized and managed rather than one-battery-per-device. A central rechargeable battery, a conformal worn battery or a squad smart battery, feeds a power manager or smart hub that distributes power and data to every connected device through several input and output ports, while a dedicated scavenging port recharges the central pack from solar, vehicle, primary-battery or AC sources.
Key fact 3. The worn batteries are smart and, in the hard-shell squad format, dual-voltage. A squad battery contains two independent sections that can be arranged for a low or a high bus, talks over the SMBus smart-battery protocol with full protection and a fuel gauge, and the conformal version is thin and flexible so it sits against a front, back or side ballistic plate.
Key fact 4. The battery sees a mixed load rather than a flat one: long low-power watch and standby broken by short high-current bursts when a radio transmits, a computer peaks or a sensor fires. The manager unifies the different device voltages onto one rechargeable pack and recharges it in the field, which is how the number and weight of carried cells are reduced.
Key fact 5. The honest chemistry split is clear. The worn primary cells are lithium primaries and the rechargeable worn packs are lithium-ion, which is not a place to claim nickel-metal hydride. Sealed NiMH is the defensible choice one layer out, in rechargeable training packs, garrison and multi-bay chargers, AA/AAA-compatible accessories and legacy gear, and in dock and solar-gateway buffers, where simple charging, abuse tolerance and not-restricted shipping matter more than the highest worn energy density.
The first principle is to understand why the system exists at all. A dismounted squad operating away from resupply has traditionally carried enough batteries to sustain every personal device for up to seventy-two hours, and because each device was designed around its own disposable cell, the soldier carried many batteries of many different types rather than one common energy store. Published logistics analysis puts a typical seventy-two-hour combat load at up to twenty-three batteries with a total weight near ten pounds, about 9.8 percent of a 102-pound combat load, and wider burden studies note that the average soldier already carries at least sixty pounds of gear, with extended-patrol personnel often carrying twice that.
This is not only a weight problem. A stack of disposable single-use cells is a logistics burden as well: many part numbers have to be forecast, shipped, issued and disposed of, and partially used cells are hard to assess, so usable energy is often thrown away. The whole direction of modern soldier power follows from this: replace the pile of disposable cells with fewer, lighter, rechargeable central batteries, manage them intelligently, and standardise the interfaces so energy can be shared and recharged rather than carried and discarded.
| System element | Job it does | Typical form |
|---|---|---|
| Central worn battery | Stores the mission energy for all devices | Conformal flexible pack or hard-shell squad battery |
| Power manager / smart hub | Distributes power and data, manages charging | Pocket manager with several I/O ports |
| Harness / vest integration | Carries power and data cabling on the body | MOLLE vest, e-textile harness, cables |
| Chargers | Recharge batteries in garrison and field | Universal, multi-bay and bulk chargers |
| Scavenging | Recover energy from solar, vehicle, found power | Foldable solar blanket, adapters |
The modern design is organised around a central energy store rather than independent cells. A rechargeable battery, worn against the body or carried in the squad's kit, connects to a power manager that runs a set of power-management algorithms. The manager takes the single battery voltage and converts it to the different voltages each device needs, distributing power and data across several output ports, and it monitors state of charge and battery health over SMBus and USB. Published manufacturer material states that a worn squad manager can power more than two hundred types of electronic equipment and can charge or scavenge a wide range of military batteries at the same time, so it powers devices while it recharges.
The integrated system version extends this into a single power-and-data architecture. A program of record integrated soldier power and data system uses the central conformal battery as its source and distributes power and data to radios and other worn connected devices through five input and output connections, optimising the distribution to everything attached. Instead of swapping a disposable cell per device, the soldier keeps one central pack charged and lets the manager do the conversion, which is the mechanism that cuts the number of batteries carried.
The hard-shell squad rechargeable battery is a smart battery. It contains two independent low-voltage sections that can be connected externally for either a low or a high bus, so the same pack supports equipment built around either rail; it implements the SMBus smart-battery protocol and protects against over-current, over-voltage, over-temperature, under-voltage and short circuit, with cell balancing and a segmented fuel-gauge display. Published data for a fielded squad battery give a nominal 14.8 and 29.6 volts across the two modes, a capacity of 15.6 and 7.8 ampere-hours, about 230 watt-hours of energy, and a weight near 1.5 kilograms, with a life beyond 300 cycles to 80 percent capacity.
The conformal wearable battery takes a different mechanical route. It is a rugged, ergonomic and flexible pack that provides about 150 watt-hours, and its thin, lightweight, bendable construction lets it conform to a soldier's front, back or side ballistic plates rather than sitting as a rigid box. The published program goal is to sustain dismounted operations in remote areas for up to twenty-four hours while reducing the weight and quantity of batteries carried, and the fielded design is a 14.8-volt lithium-ion pack built against the rechargeable-battery performance specification. A newer small-form-factor common battery family then adds eight sizes that share one mechanical and electrical interface, from roughly eleven to eighty-six watt-hours, for handheld and helmet devices.

Power has to reach the devices without a tangle of separate cables, and the harness is the part that solves this. Earlier integrated systems, such as the soldier worn integrated power equipment system, placed a power-distribution network fed by rechargeable and zinc-air batteries into the modular tactical vest, powering the electronics directly and charging secondary batteries at the same time, with a claimed weight reduction near thirty percent. Modern systems use smart hubs and electro-textile garment networks that reduce cabling and let common bearer and end devices plug in and work without reconfiguration.
Interoperability is then secured by standardised interfaces rather than bespoke adapters. The NATO standard STANAG 4695, electrical interface specifications for dismounted soldier systems, defines the mechanical and electrical features of the power connection, including voltage levels, pin assignments and connector geometry, so batteries, radios, computers and power-distribution units from different sources can work together and coalition soldiers can share energy. The same open-interface logic drives the common small-battery family, which uses one electrical and mechanical interface across all its sizes.
| Battery | Chemistry / type | Published character |
|---|---|---|
| BA-5590 primary | Lithium sulfur dioxide, non-rechargeable | About 14/28 V, 12.8/6.4 Ah, near 1.05 kg, 10-year shelf |
| BA-5390 primary | Lithium manganese dioxide, non-rechargeable | About 15/30 V, 50-100% more mission time than BA-5590 |
| Squad smart battery | Lithium-ion, rechargeable, SMBus | 14.8/29.6 V, about 230 Wh, near 1.5 kg, dual sections |
| Conformal wearable battery | Lithium-ion, rechargeable, flexible | About 150 Wh, 14.8 V, conforms to ballistic plates |
| Common small battery family | Lithium-ion, rechargeable, common interface | Eight sizes, roughly 11 to 86 Wh, USB power delivery |

When the worn system is reduced to its electrical shape, the central battery sees a mixed current rather than the steady draw of a measuring instrument. Most of the time the devices are in watch or standby at low power, and short high-current events occur when a radio keys its transmitter, a computer runs a processing peak or a sensor takes a reading. The power manager does not remove these pulses; it lets the central pack deliver them while holding every device at its correct voltage, and it recharges the pack whenever a scavenging source is available. Published squad batteries are built for high pulse discharge as well as sustained capacity, which is why they can feed manpack radios and sensors alongside handheld devices.
This profile shapes the design philosophy. The mission is met less by carrying a large reserve of disposable cells and more by keeping a smaller rechargeable central pack topped up through field scavenging, with the manager able to power and charge at the same time. Solar blankets and vehicle power become part of the energy plan when resupply is delayed, and the weight-reduction figures quoted for worn systems, around thirty to fifty percent in program material, are project targets rather than guarantees and are treated as such. Any current or runtime that is not a published specification is labelled illustrative.
The supporting equipment keeps the central packs usable. A universal battery charger is a program of record, scalable charger that handles a wide range of military and commercial batteries and adds new ones through software, with a base unit near six pounds that fits a rucksack or mounts on a vehicle; multi-bay and bulk chargers handle many cells at once and reduce the logistics footprint. The charger manufacturers note that the same charger can support several chemistries, including nickel-metal hydride and lithium-ion, because each chemistry is given its own controlled charging profile.
Scavenging extends the energy beyond what is carried. A squad manager provides dedicated scavenging ports optimised to harvest energy from solar panels, primary batteries, vehicle batteries, chargers and other found sources, and foldable solar blankets recharge the worn batteries across two output ranges. Adapters connect the conformal battery, the squad battery and the common small family to radios and helmet devices, so energy can be moved between systems rather than left stranded in a cell that no longer fits a device.
The published data establish what the worn batteries actually are. The disposable cells are lithium primaries, lithium sulfur dioxide and lithium manganese dioxide, chosen for high energy density, long storage and good low-temperature service, and the rechargeable worn packs, the squad smart battery, the conformal battery and the common small family, are all lithium-ion. The honest statement is that lithium is the chemistry on the worn front line because its high energy density keeps the load light and the mission usable, and sealed nickel-metal hydride is not claimed in that space.
The genuine nickel role begins one layer out, and it includes a real training logic. Rechargeable nickel packs can be cycled repeatedly at low unit cost and without hazardous-goods restrictions, so they replace expensive disposable lithium primaries that would otherwise be consumed in training; they also fit garrison and multi-bay chargers, AA/AAA-compatible accessories and legacy devices, and dock and solar-gateway buffers, because a sealed nickel cell holds a flat 1.2-volt platform, tolerates overcharge and rough handling, contains no cadmium and no free liquid, and ships not-restricted. The trade-off is lower energy density, so a nickel pack needs more cells and is heavier than an equivalent lithium pack, which is exactly why it belongs in training, support and fixed equipment rather than in a front-line worn battery.
The environmental boundary is stated plainly. The worn lithium systems are built for wide temperature windows, with squad batteries discharging across roughly minus thirty to plus sixty degrees and some primary cells rated near minus forty. Sealed nickel-metal hydride is less prone to permanent cold damage than lithium and retains a usable share of capacity, but low temperature still reduces the capacity available and charging has to be controlled, with a practical rechargeable nickel field limit around minus twenty degrees. No claim is made that a sealed nickel cell outperforms the worn lithium battery on energy density or weight; its honest strength is repeated use, simple recharge and not-restricted handling in equipment that comes back.
The scope is stated rather than stretched. Sealed NiMH is not offered as the worn front-line battery, where lithium is the correct choice, and it is not offered as a replacement for a squad smart battery or a conformal wearable battery. The genuine applications are rechargeable training packs that replace consumed disposable primaries, garrison and multi-bay chargers and docks, AA/AAA-compatible accessories and legacy gear, and buffer packs in power-management docks and solar gateways. All of these return and recharge, which is the condition under which the nickel chemistry pays off. Within that scope the mixed standby-and-burst load is well matched to a robust sealed nickel cell.
It is the burden created when every worn device has its own disposable battery. Published logistics work records up to twenty-three batteries weighing about ten pounds for a seventy-two-hour load, on top of an average sixty-pound gear burden, plus a large disposal and resupply footprint. Modern soldier power answers it with fewer central rechargeable packs, smart management and standardised interfaces.
A central rechargeable battery feeds a smart power manager that converts its voltage to the level each device needs and distributes power and data across several ports, while dedicated scavenging ports recharge the pack from solar, vehicle, primary or AC sources. The manager can power devices and charge batteries at the same time and can support more than two hundred device types.
A hard-shell squad rechargeable pack built from two independent sections that can be arranged for a low or a high bus, communicating over SMBus with full protection, cell balancing and a fuel gauge. A fielded example gives 14.8 and 29.6 volts and about 230 watt-hours; the conformal version instead uses a thin flexible 150-watt-hour pack that sits against a ballistic plate.
A mixed standby-plus-burst profile: long low-power watch with short high-current events when a radio transmits, a computer peaks or a sensor fires. The manager lets the central pack deliver the pulses while keeping every device at the correct voltage, and recharges it in the field rather than relying on a large reserve of disposable cells.
The disposable cells are lithium primaries and the rechargeable worn packs are lithium-ion, chosen for high energy density and light weight. Sealed nickel-metal hydride is not claimed in the worn front-line role; its honest place is in rechargeable training packs, garrison chargers and docks, AA/AAA accessories and legacy and buffer equipment.
The device taxonomy and burden figures draw on published PEO Soldier and DEVCOM references, manufacturer data and logistics analysis covering the battery-proliferation problem, the centralized managed architecture, smart dual-voltage and conformal batteries, harness and vest integration, and the STANAG 4695 interface. The battery figures, including the roughly 230-watt-hour squad battery and the 150-watt-hour conformal pack, and the seventy-two-hour burden of up to twenty-three cells near ten pounds, are published values rather than measurements of a named product, and the load levels in the figures are illustrative. Nickel cells and packs are qualified to IEC 61951-2 and IEC 62133-1 and ship under UN 3496 with the IATA A199 not-restricted air path, while the worn lithium batteries follow their own lithium transport rules. No statistics have been invented.
Weijiang Power supplies sealed NiMH cells and assembled NiMH packs for rechargeable training batteries, garrison and multi-bay chargers and docks, AA/AAA-compatible accessories and legacy gear and buffer packs in power-management and solar-gateway equipment, built to the device geometry at the required voltage with PTC and resettable-fuse protection. The cells are qualified to IEC 61951-2 and IEC 62133-1 and the packs ship under UN 3496 with the not-restricted air path under IATA A199. We do not present NiMH as a worn front-line battery, and we do not manufacture lithium-ion cells; lithium work is pack assembly only. Send us your device list and bus voltages, measured standby and burst currents, expected mission length, temperature range and charging arrangement, and we will work through the chemistry match, cell count and pack design and support the evidence for your evaluation. See the Weijiang NiMH product range for standard pack formats, or contact our OEM team with the device specification and load profile.